Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 691 of 5497

IP Quorum allow a chance to increase logging size 2. why is the application based on outdated java runtime

1. Customer would like a way to increase the size of logging for the ip quorum application for troubleshooting .2. why is this application based on an older java runtime .
over 3 years ago in IBM Spectrum Virtualize / FlashSystem 1 Future consideration

Spectrum Virtualize: SCSI ID consistency and uniqueness

#1 Host-clusters ensure SCSI ID consistency for volumes presented to clustered servers; when volumes are migrated to non-clustered storage systems the consistency needs to be maintained. This consistency is critical for VMware stability #2 When mu...
over 3 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Event notification capability to mark a hardware/software event as "Acknowledged/Unfixed" to suppress daily ongoing notifications until able to be resolved.

Current Spectrum Virtualize Software behavior: When an event is triggered/logged for a hardware/software failure or pending failure it causes SNMP notification to our in-house Monitoring system that triggers a call out notification to the Team (as...
about 2 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

Integrate recommended Storwize multipath settings into Linux multipath defaults

Update the default multipath settings applied to any 2145 devices attached to a linux system to match the recommended settings advised by IBM IBM Storwize is the only storage type currently in this organisation where the vendor recommended setting...
almost 5 years ago in IBM Spectrum Virtualize / FlashSystem 1 Planned for future release

expandvdisksize include a -finalsize instead of -size

RFE for expanding an FS900 volume via the CLI (doesn't allow New Total, Grow by, or Current Size) like GUI does. Ask them to allow "New Total" parameter NEW_SIZE instead of EXPAND_BY
almost 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

Update OpenSSH in the SpecV / FlashSystem firmware to allow the sftp protocol instead of scp

Our managment servers are based on RHEL. Which will be upgraded to RHEL9 soon. With RHEL9 the standard scp is depreciated.. (https://www.redhat.com/en/blog/openssh-scp-deprecation-rhel-9-what-you-need-know) With updating the openssh version within...
9 months ago in IBM Spectrum Virtualize / FlashSystem 0 Under review

Ethernet port failure not generating events within a specific time frame

jeffos (IBM)Oct 04, 2022, 13:43 Hello team, I have discussed this with our SME team and they do agree that since shared technician ports aren't used on the newer platforms, setting a shorter timeout seems sensible. They suggest to submit a Request...
about 2 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration

System managed throttles

Volumes throttling is managed at a canister/node level such that a throttle for a volume or server is the sum of what both canisters can deliver. If a canister were to fail the throttle can only deliver 50% of the original value. The throttle shou...
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 1 Future consideration

IP Quorum message when deamon stoppes running or VM is down.

After setup IP quorum in a Stretched cluster environment there is no warning\error or message when the VM is down or deamon stopped running. So a message or event is needed to take action to start the IP quorum again.
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

Support end user activation for HyperSwap relationship suspension and activation to allow batch workload best performance

Spectrum Virtualize HyperSwap current implementation does not allow selectively pausing/activating active-active replication for a volume or a consistency group protected by the HyperSwap mechanism. This forbids clients to host latency sensitive w...
over 3 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration