Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 684

Powering a node on remotely

Sometimes we need to power off a node for testing purposes and we have no option to power the same node on after we are done with the testing..
3 months ago in IBM Spectrum Virtualize / FlashSystem 0 Under review

Populate user friendly naming convention & protocol on notification - GUI enhancements

Hello IBM Team, We came across the notification which shows the "Ethernet port failure" but in details sections the Event ID Text has "Fewer ethernet ports operational" but its not populating the right naming convention & right protocol type t...
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration

Auto create replication target volume when establising new metro/global mirror

When creating a new metro or global mirror relationship , allow the option to automatically create the target volume similar to how flashcopy has the option.
about 3 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Safeguarded Copy checking mechanism

Our client is suggesting the following enhancement: inside SGC code define a checking mechanism to exactly point out the bad sector(s) or block(s) or LUN(s) potentially affected that will be isolated or made invalid and then provide a a valid copy...
about 3 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Increase StripeWidth when expanding DRAID

Increase the stripe width when expanding a DRAID to maximize the capacity.
over 3 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Increase SVC Storwize host limit per IO group

We have exhausted the maximum number of hosts definitions per IO group - 512. Many of the hosts in our large enterprise have volumes defined from various IO groups and we have the need to define hosts in more then one IO group. It's critical and e...
almost 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SVC Host Path Check Pause

Provide a button to move on from path checks during an SVC upgrade. Have upgrade check to see if hosts even exist on the cluster and if no don't pause for path check.
about 9 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SVC Global Mirror, moving B copy to another I/O Group without forcing a resync. (SYS4955)

SVC Global Mirror -Ability to able to move B copy LUNs (target site GM LUN) to another IOGRP without forcing a complete re-sync.
almost 10 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

SVC Vdisk Migration Refusal Stopgap

SUBMITTER SECTIONFIT Number: MR1204071911User Marketing Field Requirement Number: MR1204071911Title: SVC Vdisk Migration Refusal StopgapSubmitted By: Wesley Wempner/Dallas/IBMOriginators Area: pSS CenterFPOC: Barbara McDonald/San Jose/IBM Erika Da...
over 10 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration

Allow SVC to recover backend unused thin vdisk

Kohls has found that when you run 'create vdisk' they have the option to 'format' the vdisk which puts all 'zeros' on volume,backend disk subsystem then ignores the zeros.Kohls uses some 3Par backend storage which is 'thin' aware. To fully recover...
over 9 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration