Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 690

Repeat email alerts are often indistinguishable from "new" email alerts. Add the word "Reminder" to subject line.

The SVC will send reminder notifications about errors/events that have not been "Fixed" every 24 hours. When these reminder emails are received, the text in the subject line is exactly the same as the original email notification. This duplication ...
about 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

Host across ownership group

Customer replaced A9000 with FS9500 and runs into this issue: on SpVirt, the host object is part of the ownership group (tenant domain) (<> A9 did not consider hosts as part of the 'tenancy domain'). There is a manual workaround (chghostcl c...
about 2 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

DRP Pool -> Migrate vDisk between DRPs

Introduction of the migratevdisk command for DRP pools.
about 6 years ago in IBM Spectrum Virtualize / FlashSystem 3 Not under consideration

DRP Pool -> show internal volumes in vdisk list or on a seperate list

Producing transparency, not just accounting for the consumption of internal volumes in the pool, but displaying those volumes in the volume list of consumptions.
about 6 years ago in IBM Spectrum Virtualize / FlashSystem 1 Future consideration

SVC GUI enhancement request

In the SVC GUI - when viewing hosts:The host mappings column shows a no or yes and disk symbol. Suggested change:Also display the number of volumes that are lunmasked.
about 10 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

IBM V3700 Storewize Email functionality

Hello Team, Currently, our storewize has been configured with email feature under the path (Notifications --> Email configured) and we do receive "Alert Event Notifications" whenever there is an issue/event generated within Storewize like Drive...
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

debug capability for Cloud Object Storage from Spectrum Products

Our team configures Transparent Cloud Tiering - Cloud Object Storage Connection from Spectrum Storage Products (SVC, Virtualize, FS9100, A9000, V7000, V5000).
about 6 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

StorM performance evalution problem

StorM evaluates performance better than the actual machine.StorM evaluates at 300,000 IOPS or more/1 msec or less under the following conditions. The bottleneck is CPU Utilization.FS7200, 4.8TB FCM x 13, DRAID6, Read:Write=99%:1%, Block size=6KiB,...
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SNMP Query support for Storwise V3700

The V3700 SNMP Implementation only pushes management/monitoring information. We have a large OEM Opportunity that requires the ability to pull SNMP data for automated management purposes. SNMP exposes management data in the form of variables on th...
over 10 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

CLI to set Restful API requests limits

As for now request limits for restful API are hard-coded in SVC. See table in https://www.ibm.com/docs/en/sanvolumecontroller/8.5.x?topic=svc-spectrum-virtualize-restful-api. For some use cases it makes sense to set the limits higher to enable aut...
about 2 years ago in IBM Spectrum Virtualize / FlashSystem 3 Future consideration