Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 689

V9000 - stopfcconsistgrp command with force option cancelled flash-copy tasks on another consistency group !

Our V9000 All Flash Array has two flash-copy consistency groups. 1. Used for daily backups ( Oracle hot backups )2. Used for a QA refresh. On 8/4/2016, we did a QA refresh of 14TB using consistency group 2. copyrate was set to 50, we estimated it ...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Ability to setup SVC cache prefetch on a per volume basis.

When there is a need to disable cache prefetch, the only option available today is setting a parameter that takes effect accross the entire system (cluster). There are cases where cache prefetch is not beneficial (examples: colliding (overlapping)...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Create Hyperswap with GUI

When creating Hyperswap volumes with the GUI only the sourcevolume get a speaking name. The auxilary copy and the Changevolumes are named by defaults (vdiskXX). It would be more helpful to have the same name with suffixes as the sourcevolume has.
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Ability to auto-restart SVC Global/Metro Mirror relationships.

When a problem occurs that leads to either a SVC 1720 or 1920 error, the Global/Metro Mirror relationships automatically stops. The options available today to deal with this case is either to manually restart the relationships or develop and imple...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Restore Volume Mapping Feature to Volumes Section

Recently we upgraded our SVC clusters from V7.4.0.3 to v7.6.1.1. In the v7.4 release, it was possible to map a volume at the time of creation to many hosts, while specifying the LUN ID. It was also possible to edit a volume's LUN ID after creation...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Volume based on/off cache prefetch

Erste Group is building up the new HW and SW infrastructure for corporate DWH system For hot data they are using 8 node SVC (model DH8) cluster and FlashSystem 840 as the SVC back-end Tier0 storage. For the cold data (Tier 1) they are using the sa...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SVC log entry when a node starts running on UPS

When AC power is lost and UPS ride through begins we post msgs to a log that is only available in the SNAP. We need messages posted in SVC error log also so that client can easily see instances where this may be occurring. Ideally, we would immedi...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

SVC upgrade test utility usage design change

1. The svcupgradetest utility currently does not allow the "-f" and "-v" flags to be used together on the same command line. Currently the "-f" flag can only be used with the "-d" flag. When the "-f" and -v" flag are used simultaneously, such as "...
almost 9 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Silent mode for STAT tool

With the Heatmap STAT tool would be the ability to have it run in silent mode. In its current state, it has to be run interactively and someone has to hit return for it to complete which makes scripting difficult.
almost 9 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

VDISK mirror status monitoring

- vdisk mirror syn status - want to be able to see when the 2 copies for the mirror are in/out of syn via log - vdisk mirror parameter adjustment - latency vs. redundancy each have a timer setting for suspend....
almost 9 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration