Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

All ideas

Showing 5423

v5000 shows as 2076 instead of 2078 when zoned to SVC

When customer adds a V5000 backend stores and zones to the SVC, it shows as a 2076 (V7000) instead of 2078 (V5000). Customer would like this to represent the correct M/T for the storage type added.
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Present option for high performance Volume Group Snapshots

IBM i workloads and Epic Cache/Iris each have blueprints and best practices to use 64KB grain sizes for Thin Provisioned volumes and FlashCopy grain sizes. This is done with traditional FlashCopy and mkvdisk commands through the CLI. There are no ...
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 0 Planned for future release

Make reports that are saved into the report folder available via the GUI

Many people don't login to the Control host when accessing Control, it's more common accessed via a web browser. If your environment hasn't been setup for email it makes accessing reports very difficult. Especially when you don’t want regular emai...
over 1 year ago in IBM Spectrum Control 0 Future consideration

Spectrum Protect on LinuxOne with RHEL 8.x

LinuxOne is proposing for Oracle database consolidation, Spectrum Protect is a key component to provide data backup and recovery. The compatibility of Spectrum Protect on LinuxOne with RHEL 8.x is essential for the proposal.
almost 3 years ago in Storage Protect Family / Spectrum Protect (Server) 4 Planned for future release

parallel threads of volume / vdisk migation in SVC GUI

It is not possible to change the amount of threads for vdisk / volume migrations between mdiskgroups / pools inside the SVC GUI version 6.x
over 12 years ago in IBM Spectrum Virtualize / FlashSystem 4 Not under consideration

Add confirmation question for restart in Administrative Console - System Management

If accidently clicking on the "Restart IBM Spectrum Proctect Plus" it will happen instantly. I think it would be better with a confirmation here instead of using "hot" buttons.
over 1 year ago in Storage Protect Family / IBM Spectrum Protect Plus 1 Future consideration

Hyper scale manager CSR Generation

This is for IBM Hyperscale manager application request for CSR generation for certificate renewal We don't find any option so we logged a case with IBM spectrum control
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

allow users to add a delay to trigger ESC quorum race in case of sites being disconnected to allow for SAN re-connection

allow users to add a few seconds to the SVC re-try and decision process before triggering a quorum race in case of loss of connection between sites. This would allow redundant inter-site connection to complete SAN connectivity between sites fail o...
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

add fast format (quick format) in SVC

Please add quick format (or fast format) on spectrum virtualize platforms similar to as it's implemented currently on DS8000.
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

Using DB2 JSON functionality in Spectrum Discover

We've found a need for more complex tag values in our use cases for Spectrum Discover. An example of this is the ability to associate an entity with a document, where the entity has its own attributes. One such entity could be a "creator", with at...
almost 3 years ago in Storage Discover 0 Not under consideration