Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 691

Restore SVC GUI (7.6/later) to have Volume Overview tab with information as pre-7.6 changes

Volume Overview Tab – Appears when we right click a volume. Missing in 7.6. Please refer first screenshot in the below email. Unfortunately there is no equivalent to this in 7.6 and later. All the information is available only on different screens...
over 7 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Include preferred node ID in standard CLI-listing of all vDisks

Can we include the preferred node ID in the standard listing about all vDisks in the SVC cluster, which can be requested via CLI command -lsvdisk ? The averall listing should include this as standard output, but it could be de-selected by using fi...
over 11 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

SVC to have fail safe code if someone is trying to compress data that is not compressible. Applicable to V7000 too.

The SVC, and V7000 needs some sort of safety measure for the Realtime Compression feature. If the customer is trying to compress something that is not compressible, then the SVC/V7000 should be able to recognize it as such, stop it's compression e...
over 11 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration

Planned deletion like rmmdisk of mdisks before removing them from SVC cluster

It would be very helpfull te prevent unwanted alerts and events when removing mdisks from a SVC cluster. Currently, when removing mdisks from a cluster, you make sure the mdisks are unmanaged, then you de-provision them from the back-end array, wh...
almost 12 years ago in IBM Spectrum Virtualize / FlashSystem 3 Not under consideration

Senior Technical Specialist

Add another Security Role.The Role is the same as Monitor with the added function of "Download Support Package".
almost 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

V7000 Hyperswap reduced FC connectivity between Sites

The V7000 with Hyperswap configuration with no ISL. Two V7K enclosure implemented for two site with NO ISL configuration. Two site has been connected each other via 4 FC link . The connectivity is limited with 4 FC cables instead of 8 FC cables an...
about 8 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

SVC - Flashcopy incremental sync report sizes

Currently when taking a SVC Flashcopy snapshot there's no way of recording or reporting how much was copied from the source to target vdisks.
about 12 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

"-all"-Flag for "repairvdiskcopy -resync"

Enhancement for the command "repairvdisk -resync" with a flag "-all", which automatically includes all vdiskcopies which are not in sync.
about 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SpecV queue full condition not being properly retried/recovered by MSDSM

Ian Mac Quarrie and Bill Passingham are aware of this issue at GEICO. Spectrum Virtualize in combination with Windows MSDSM is currently experiencing issues when Spectrum Virtualize hits a queue full condition. This condition needs to be fixed.Bil...
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Is a defect

SVC Auto balance

We have 4 IO/Groups under one stretched cluster ; we experienced some performance issues and the support team advised to migrate LUNs between the nodes; this is unfeasible as administrator can never balance the nodes manually , SVC should be aware...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration