Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 676

Show warning for mismatching "local fc port mask" upon attempt to add nodes to an existing cluster

Attempt to add nodes to an existing system failed with the candidate nodes being stuck in "adding" forever. This was caused by the configured "local fc port mask", which restricted the inter-node I/O to certain FC port ids. There was no hint, erro...
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

allow users to add a delay to trigger ESC quorum race in case of sites being disconnected to allow for SAN re-connection

allow users to add a few seconds to the SVC re-try and decision process before triggering a quorum race in case of loss of connection between sites. This would allow redundant inter-site connection to complete SAN connectivity between sites fail o...
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

add fast format (quick format) in SVC

Please add quick format (or fast format) on spectrum virtualize platforms similar to as it's implemented currently on DS8000.
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

parallel threads of volume / vdisk migation in SVC GUI

It is not possible to change the amount of threads for vdisk / volume migrations between mdiskgroups / pools inside the SVC GUI version 6.x
over 12 years ago in IBM Spectrum Virtualize / FlashSystem 4 Not under consideration

SSD host identification for IBM i

SSD Host identification for IBM i is very crucial for customer who have invested in SSD in DS5000 and DS8K.
about 11 years ago in IBM Spectrum Virtualize / FlashSystem 2 Not under consideration

Storage Target Selection for Comprestimator CLI and GUI

SPectrum Virtualize provides Comprestimator statistics on board the Spectrum Virtualize layer based on RACE algorithm. There e are other possible hardware / software compression targets (FS900, FS9100, ...) for which Comprestimator is available in...
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Concurrent failover of SVC Config node

Currently if the SVC cluster needs to fail over the config node it causes the hardware node that is the config node to reboot. This can expose problems to the paths and servers connected to this node, which can lead to loss of access or the necess...
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Log failed commands in auditlog or syslog

We are increasingly working with applications that "talk" to the SVC (and FlashSystems). In case of problems, we try to find out which commands these applications used.Commands that have failed are not logged, while this can be important informati...
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 2 Functionality already exists

Capacity Threshold Alerting

The monitoring "Threshold" only allows for a single value to be set, not a second value. Example. Warning Threshold is set to 70%, when the pool exceeds 70% a Warning level severity alert is send. There is not an option to set a second threshold a...
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

Digital Encryption Key delete notification upon pool or rank removal

Upon child pool deletion (or rank deletion) CLI response and GUI popup will display a confirmation message that confirms the deletion of the encryption key and constitutes NIST compliant crypto erasure.
over 5 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration