Skip to Main Content
IBM System Storage Ideas Portal


This portal is to open public enhancement requests against IBM System Storage products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

IBM Spectrum Virtualize / FlashSystem

Showing 691

SVC to allow more than 4 remote partnerships

In current situation an SVC cluster can only have 3 Remote Copy partnerships. Proposed resolution: Enlarge the number of RC partnerships Business impact: RC connection between more than 4 SVCs
over 7 years ago in IBM Spectrum Virtualize / FlashSystem 1 Planned for future release

possibility to influence SVC quorum promotion

We would like to have the possibility to influence on which site the disc quorum will be promoted to active, once all IP quorum are not eligible quorum anymore.
over 1 year ago in IBM Spectrum Virtualize / FlashSystem 4 Not under consideration

Add CIFS/NFS to spectrum Virtualize

Hello,A lot of customers are disappointed with the lack of files protocols on midrange storage.With the end of sales of V7K unified we are facing a major issue. All competitors are providing equivalent solution, and I think that building a solutio...
almost 6 years ago in IBM Spectrum Virtualize / FlashSystem 1 Not under consideration

DRP support for compressed volumes with Enhanced Stretch Cluster

Currently due to latency considerations on an Enhanced Stretch Cluster (SVC) we are unable to leverage DRP and use compressed and/or deduplicated volumes. 8-node SV1 enhanced stretch cluster, FC connected with X6-8 Brocade core switches and data c...
about 4 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

You are not warned of IOGrp Overload

Storwize will let you continue to add volumes to an overloaded IOgrp. There are no limits in this area which means you can add more work to an already stressed IOGRP. There is no balance either meaning one IOgrp can be over loaded while other IOgr...
almost 6 years ago in IBM Spectrum Virtualize / FlashSystem 0 Future consideration

User set replication bandwidth allocation per IO group

Today SVC allocate a equal share of the partnership bandwidth to all IOGRP in a cluster.This RFE is to allow a user to set a different share (percent) of the overall bandwidth to different IOGRP
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SVC GUI Storage pool Capacity Reporting

IBM SVC GUI capacity report of safeguarded storage pool used capacity is based on total - Free capacity. This doesn't align with CLI lsmdiskgrp accurately. Request is to have exact match of capacity numbers such as USED, REAL and Total capacity in...
over 2 years ago in IBM Spectrum Virtualize / FlashSystem 1 Future consideration

Uptime command

a "uptime" command that shows system uptime - perhaps lssystemuptime, if possible with several options to show uptime for nodes / drives / ports and other components
over 8 years ago in IBM Spectrum Virtualize / FlashSystem 2 Future consideration

SVC stretched cluster learning Easy Tier heatmap on secondf copy of Vdisk mirror

Easy Tier considers each pool separately, without knowledge about mirrored VDisks. In a stretched cluster with full site awareness and host failover cluster as application, the pool in the production site (where the host failover cluster lives mos...
almost 8 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration

SVC stretch cluster volume select preffered node

When creating a new SVC stretch cluster volume, the site location (or the preferred node ID) cannot be selected. Also, it cannot be set until after the format of the volume is done. But can be changed at a later time using movevdisk.We need a func...
about 7 years ago in IBM Spectrum Virtualize / FlashSystem 0 Not under consideration